FAQ

FAQ

1.How do you control the quality?
Our production strictly follow ISO9001 quality control system.after four time qulatiy inspect and high temperature testing we will print “QA"pass.also we have ERP system for more convinent management&Delivery control.
2. What’s the productionability?
8000 pieces monthly and rush order for any quantity.
3.What is the standard of package?
Export standard package or special package with requirement
4. Do you accept OEM business?
We accept OEM&OBM&ODM with your authorization.
5. How is the after-sale service?
We offer spare parts accordingly and English-speaking engineer offer online service.
6. Which market do you already sell?
We already ship to many African countries, Middle East, South America, Southeast Asia etc.
8. Explain the reasons for the slow speed of the motor when starting up.

When the motor starts, the speed is slow, there may be several reasons, here are some common situations:

  1. Low voltage of power supply: The motor requires higher voltage during startup to provide enough torque to overcome inertia and inertial forces. If the power supply voltage is too low, the motor will not be able to obtain enough torque, resulting in slow startup speed.

  2. Excessive starting current: If the motor requires excessive current during startup, it may cause the power supply voltage to drop, thereby affecting the startup speed.

  3. Overload: If the load is too heavy, the motor needs to overcome greater resistance to start, resulting in a slower startup speed.

  4. Mechanical issues: There may be mechanical issues inside the motor, such as bearing wear, rotor eccentricity, etc., which can also affect the motor’s startup speed.

  5. Incorrect starting method: If the motor starts with no load, it may start slowly from zero speed; if the direct starting method is used, it may also affect the motor’s startup speed.

If the motor starts slowly, it is recommended to gradually investigate the possible reasons mentioned above, check the power supply voltage, load conditions, mechanical conditions, etc., to identify the problem and perform the necessary repairs or adjustments.

  1. Selection of Brushes for Wound-Type Asynchronous Motor Rotor Collector Rings

The rotor collector rings of wound-type asynchronous motors usually require brushes for decarbonization and maintenance. When selecting brushes, several factors need to be considered:

  1. Material: Brushes are typically made of materials such as carbon and graphite. Carbon brushes are cost-effective and suitable for general applications. Graphite brushes offer high-temperature and wear-resistant properties, making them suitable for motors operating at high speeds and loads.

  2. Hardness: Brushes should have moderate hardness. Too hard brushes may cause wear on the rotor collector rings, while too soft brushes may generate debris during operation. Therefore, brushes of moderate hardness should be chosen.

  3. Conductivity: Brushes should have good conductivity to ensure proper contact for current conduction.

  4. Wear Resistance: Brushes should have good wear resistance to reduce wear between the brushes and collector rings, thus extending their service life.

  5. Size: The size and shape of brushes should match the dimensions of the collector rings to ensure proper contact and conduction.

When selecting brushes, factors such as the motor’s operating environment, working conditions, and the material of the rotor collector rings should be taken into account. It is advisable to choose brushes according to the reference or recommended values provided by the motor manufacturer to ensure proper operation and maintenance of the motor.

  1. Meaning of ‘Z’ and ‘TH’ in Transformer SFZ-32000/220TH

In the transformer model SFZ-32000/220TH, ‘Z’ and ‘TH’ have specific meanings:

  1. Z: ‘Z’ typically represents “direct current grounding.” When ‘Z’ appears in the transformer model, it indicates that the transformer adopts a direct current grounding method, meaning that the neutral point of the transformer is grounded. This helps improve the safety and performance of the system.

  2. TH: ‘TH’ usually denotes Class A insulation. When ‘TH’ appears in the transformer model, it indicates that the insulation class of the transformer meets Class A requirements, meaning that the insulation level is higher and the safety performance is more reliable.

Therefore, in the transformer model SFZ-32000/220TH, ‘Z’ signifies the adoption of direct current grounding, while ‘TH’ indicates that the insulation level meets Class A requirements. These markings are important indicators for the safety performance and application scope of the transformer. When using the transformer, it is essential to make reasonable selections based on these markings and ensure compliance with the equipment’s requirements and specifications.

  1. Considerations for Using a 60Hz Motor on a 50Hz Power Supply

When using a 60Hz motor on a 50Hz power supply, several considerations should be taken into account:

  1. Rated Speed and Power: Due to the difference in power supply frequency, running the motor on a 50Hz power supply will result in a decrease in speed, which may affect the motor’s power output. Therefore, it’s essential to assess whether the motor is suitable for operation on a 50Hz power supply based on its rated speed and power.

  2. Heat Dissipation: The decrease in frequency may reduce the amount of heat dissipated during motor operation. Therefore, additional considerations regarding heat dissipation may be necessary to prevent the motor from overheating.

  3. Bearings and Lubrication: Differences in frequency may affect the motor’s bearings and lubrication systems. Ensure that the bearings and lubrication systems can operate under the conditions of a 50Hz power supply.

  4. Stability of Operation: Frequency variations may affect the motor’s operational stability, particularly during startup or fluctuations during operation. Consider the motor’s operational stability and safety.

  5. Electromagnetic Noise: Frequency changes may affect the electromagnetic noise level of the motor. Therefore, pay attention to noise issues during motor operation.

  6. Motor Protection: When using a 60Hz motor, ensure that the variable frequency drive (VFD) or other controllers can adapt to the 50Hz power supply frequency and ensure the safe operation and protection of the motor.

In summary, using a 60Hz motor on a 50Hz power supply requires careful consideration of the above factors and may require adjustments to adapt to the motor’s operating conditions to ensure safe and stable operation on a 50Hz power supply. It is advisable to consult with the motor manufacturer or professional engineers to make the correct decisions and adjustments.

  1. Purpose and Function of Output Reactor in Variable Frequency Drives

The addition of an output reactor at the output terminal of a variable frequency drive (VFD) aims to improve the compatibility and stability between the VFD and the driven motor. The functions of the output reactor are as follows:

  1. Harmonic Reduction: The PWM output of the VFD introduces high-frequency harmonics. The output reactor can limit the propagation of these harmonics, reducing their interference with the motor and power supply system, thus protecting the motor and other equipment from the effects of harmonics.

  2. Enhanced Electromagnetic Compatibility: By reducing the high-frequency noise and harmonics at the output terminal, the output reactor can enhance the system’s electromagnetic compatibility, reducing interference with surrounding equipment.

  3. Smoothing Current Waveform: The output reactor can smooth the output current waveform, reducing current ripple, enhancing the motor’s operational stability, and minimizing vibration and noise.

  4. Motor Protection: The output reactor can limit the peak current, reducing the impact on the motor and protecting it from damage due to overcurrent, thereby extending the motor’s lifespan.

  5. Improved Transmission Efficiency: The output reactor can match the impedance between the VFD and the motor, reducing wave reflection, improving transmission efficiency, and reducing energy loss.

In summary, by installing an output reactor, the stability, electromagnetic compatibility, and transmission efficiency of the VFD system can be improved. It protects the motor from the effects of harmonics and overcurrent, making it a common auxiliary device for VFDs, especially in long-distance and high-power VFD systems.

  1. Can AC Servo Motors be Controlled by Variable Frequency Drives?

In general, AC servo motors can be controlled by variable frequency drives (VFDs), but it requires careful selection and configuration based on specific requirements. Here are some factors to consider:

  1. Compatibility: The VFD needs to support the control requirements of AC servo motors. This includes support for speed, position, torque control, and interfaces for feedback devices such as encoders.

  2. Response Speed: Servo motors require very fast response to control the position, velocity, etc. The control performance and output response speed of the VFD must meet the requirements of the servo control system.

  3. Closed-loop Control: Servo motors typically require closed-loop control, which involves obtaining motion status information through feedback devices like encoders. The VFD needs to support this feedback control mode.

  4. High Precision Requirements: Servo motors are often used in applications requiring high-precision position or velocity control. The VFD needs to have high-precision control capability.

  5. Stability: Servo systems require stable operation. The VFD needs to provide stable power and control signals to ensure smooth operation of the servo system.

In summary, AC servo motors can be controlled by VFDs, but attention must be paid to the above factors to ensure the compatibility and stable operation of the VFD and servo motor. It’s advisable to consult with professional engineers or manufacturers for specific configuration and setup requirements before making equipment selections.

  1. Can Variable Speed Motors be Started Frequently?

Variable speed motors are typically used in applications where frequent starting and speed adjustment are required. They are characterized by their ability to flexibly adjust speed under different load conditions. However, frequent starting actions can have some effects on the motor and system, and the following points need to be considered:

  1. Mechanical Stress: Frequent starting imposes additional stress on the mechanical components of the motor and system, which may lead to wear or damage. Therefore, the durability and lifespan of mechanical components should be considered in design and use.

  2. Electrical Issues: Frequent starting may cause the starting current of the motor and electrical equipment to be too high, affecting system stability and the lifespan of electrical equipment. Attention should be paid to the design and protection of the electrical components.

  3. Heat Generation: Frequent starting generates more heat in the motor and system, which may affect motor cooling and operating temperature. It’s essential to ensure effective motor cooling to prevent overheating.

  4. System Stability: Frequent starting may affect the stability and efficiency of the system, and the impact of starting frequency on the overall performance of the system should be considered.

In summary, variable speed motors can be used in applications requiring frequent starting, but careful consideration of the above factors is necessary. Proper design and protection of the motor and system should be ensured to ensure stable and safe operation and prolong equipment lifespan. Additionally, in practical use, the impact on the motor and system can be reduced by controlling the frequency and manner of starting. If there are specific requirements or concerns, it is advisable to consult with professional engineers or manufacturers for advice.

  1. How Can Experts Determine if a Motor is Wired in Delta (△) or Star (Y) Connection?

To determine whether a motor is wired in delta (△) or star (Y) connection, several methods can be used:

  1. Check the Terminal Box: The delta (△) or star (Y) connection method is usually indicated on the motor’s terminal box. You can check the markings on the terminal box to confirm the motor’s wiring method.

  2. Inspect the Nameplate: The motor’s nameplate typically indicates the connection method and wiring diagram. You can review the information on the nameplate to confirm the motor’s wiring method.

  3. Inspect the Windings: By examining the structure of the motor windings, you can roughly determine whether the motor is wired in delta (△) or star (Y) configuration. In a delta (△) connection, the connection endpoints of the windings are directly connected to form a closed loop, while in a star (Y) connection, the connection endpoints are linked together via a common connection point.

  4. Measure Resistance Values: To determine the motor’s wiring method, you can measure the resistance values of the motor windings. In a delta (△) connection, the resistance values between the three-phase lines should be equal, while in a star (Y) connection, there may be different resistance values between the three-phase lines.

  5. Observe Wiring Connections: If you can access the motor’s wiring terminals, you can observe the actual wiring connections to determine the wiring method.

By using any combination of the above methods, you can accurately determine whether the motor is wired in delta (△) or star (Y) connection. It’s important to note that before performing any connections or measurements, ensure that the motor is disconnected from the power source, and it’s best to have the work done by professionals to avoid the risk of electric shock or other hazards.

  1. How Does the Number of Motor Poles Affect Motor Selection?

The number of poles in a motor refers to the number of magnetic poles on the motor rotor. The selection of poles directly affects various aspects of the motor, including its speed, torque, efficiency, and application range. Here’s how the number of poles affects motor selection:

  1. Speed: The number of poles is inversely proportional to the motor’s speed, meaning that a higher number of poles result in lower speed. Typically, motors with fewer poles are suitable for high-speed applications, while those with more poles are suitable for low-speed, high-torque applications.

  2. Torque: The number of poles is directly proportional to the motor’s output torque, meaning that more poles result in higher output torque. Motors with more poles generally provide higher starting torque, making them suitable for applications requiring high starting torque or heavy loads.

  3. Efficiency: The number of poles also directly affects the motor’s efficiency. In general, motors with fewer poles have higher efficiency, while those with more poles tend to have relatively lower efficiency.

  4. Smooth Operation: Motors with fewer poles have lower inertia and typically operate more smoothly. Motors with more poles may have higher inertia, which can lead to greater vibration during startup and speed changes.

  5. Application Range: Different applications may require motors with different numbers of poles. For example, motors with more poles are suitable for applications requiring higher torque and lower speeds, such as winding machines and mixers, while motors with fewer poles are suitable for high-speed applications like fans and compressors.

Therefore, when selecting a motor, it’s essential to consider the specific application requirements and working conditions to choose the appropriate number of poles for optimal performance and efficiency. Additionally, factors such as motor power, rated speed, and efficiency should be considered comprehensively. It’s advisable to consult with professional motor manufacturers or engineers when selecting a motor to ensure the best choice for your needs.

  1. What is a Series Wound Motor, and What is its Operating Principle?

A series wound motor is a special type of DC motor where the field winding (also known as the excitation winding) and the armature winding on the rotating rotor are connected in series in the same circuit, hence the name “series wound motor.” Series wound motors operate based on several distinct principles and characteristics:

Operating Principle:

  1. Series Connection: In a series wound motor, the field winding and armature winding are connected in series, sharing the same circuit. Typically, the field winding has fewer turns compared to the armature winding, resulting in a powerful magnetic field excitation.

  2. Self-Excitation: Series wound motors can utilize the induced electromotive force generated by the armature during initial startup to assist in field winding excitation, a process known as self-excitation. Once the motor starts and rotates, the field winding maintains the excitation state, enabling the motor to continue operating normally.

  3. Characteristics Adjustment: The characteristics of series wound motors can be adjusted by regulating the armature current and field current, allowing for some degree of control over the motor’s speed and torque characteristics.

  4. Application Range: Series wound motors are typically used in low-speed, high-torque applications such as traction machines and starters. Due to their relatively simple characteristics and lower cost, they are suitable for basic requirements.

Characteristics:

  • High Torque Performance: Series wound motors exhibit high starting torque at low speeds.
  • Limited Speed Adjustment Range: Due to the series connection of the field and armature, the speed adjustment range is relatively small.
  • High Field Excitation Requirement: Because of the fewer turns in the field winding, a relatively large field current is required for excitation.
  • Self-Excitation Capability: They possess a certain degree of self-excitation capability, enabling automatic excitation to some extent.

In summary, series wound motors are a straightforward and stable type of DC motor, typically suitable for low-speed, high-torque applications. However, due to their limited speed adjustment range, their application range is relatively restricted, necessitating careful consideration based on specific requirements.

  1. Will a Submersible Pump with a Rated Current of 12A Cause the Thermal Magnetic Protection Device Upstream to Trip if the Maximum Starting Current Reaches 227A?

Based on the description, a submersible pump with a rated current of 12A has a maximum starting current of 227A, which is significantly higher than the rated current. This high starting current may indeed cause the upstream thermal magnetic protection device to trip. Here are some considerations:

  1. Principle of Thermal Magnetic Protection: Thermal magnetic protection is an overload protection device designed to prevent dangerous situations during circuit overload. When the current in the circuit exceeds a certain threshold, the thermal magnetic protector senses the overload condition and trips, cutting off the circuit to protect it and the equipment from damage.

  2. Starting Current Exceeds Rated Current: If the maximum starting current of the submersible pump reaches 227A, this far exceeds the nominal rated current of 12A. Such a significant current surge is likely to trigger the upstream thermal magnetic protection device to trip.

  3. Circuit Stability: Large fluctuations in current can destabilize the circuit and pose a risk of damage to equipment and circuits. The design purpose of the thermal magnetic protection device is to protect the equipment under such circumstances.

Therefore, due to the high starting current compared to the rated current, the submersible pump may indeed cause the upstream thermal magnetic protection device to trip. To prevent this situation, consider taking the following measures:

  • Use a thermal magnetic protection switch with a higher rated current to accommodate the high starting current requirement.
  • Consider adding a soft starter or other starting control device to smoothly start the motor and reduce current surges during startup.
  • Check the connection status of the circuit and equipment to ensure load balance.
  • In practical use, it is advisable to have a professional electrical engineer evaluate and adjust the system to ensure the safe and reliable operation of the equipment.
  1. How to Determine the Condition of a Three-Phase Induction Motor?

To assess the condition of a three-phase induction motor, several methods can be employed:

  1. Visual Inspection: Begin by visually inspecting the motor. Check for any obvious damage, deformation, or oil leakage on the motor casing, which may indicate faults or issues.

  2. Insulation Resistance Measurement: Use a multimeter or insulation resistance tester to measure the insulation resistance of the motor. Insulation resistance below a certain value may indicate insulation problems.

  3. Measurement of Resistance Values: Measure the resistance values of the motor windings, which should typically be symmetrical. Significant deviations in resistance values among phases may indicate issues with a particular phase.

  4. Rotational Check: Manually rotate the motor rotor to check if it rotates smoothly without any sticking. Difficulty in rotor rotation may indicate bearing or winding issues.

  5. Operational Check: Connect the motor to a power source, start it, and observe for any abnormal noise, vibration, or odor during operation. Additionally, measure parameters such as operating current and power factor using appropriate instruments and compare them with normal values.

  6. Temperature Check: Monitor temperature changes during motor operation. Overheating may indicate issues with cooling or insulation.

  7. Vibration Analysis: Use vibration instruments to assess motor vibration. Abnormal vibration may indicate problems with bearings or balance.

By combining these methods, you can preliminarily assess the condition of a three-phase induction motor. For repairs or more in-depth diagnostics, it’s advisable to contact professional motor repair and testing organizations to ensure the motor’s safety and proper operation. Additionally, regular maintenance and inspection of the motor are essential measures for ensuring long-term stable operation of equipment.

  1. Can Circuit Breakers and Fuses be Installed on the Neutral Wire?

In normal circumstances, circuit breakers and fuses are not commonly installed on the neutral wire because the neutral wire is primarily used to complete the circuit, provide return current, and act as a grounding point, rather than for circuit protection. However, there are some considerations if installing circuit breakers or fuses on the neutral wire is deemed necessary:

  1. Safety: Before installing circuit breakers or fuses, ensure that there is no voltage present on the neutral wire to avoid the risk of electric shock.

  2. Suitability: Generally, circuit breakers and fuses should be installed on the phase or hot wire for overload and short circuit protection. Since the neutral wire typically does not pass through loads directly, installing circuit breakers or fuses on the neutral wire may result in misoperation or ineffective protection.

  3. Regulatory Requirements: In some regions, regulations may prohibit the installation of circuit breakers or fuses on the neutral wire. It is essential to comply with local electrical safety regulations and standards.

  4. Device Selection: If it is indeed necessary to install protective devices on the neutral wire, specialized circuit breakers or fuses designed for neutral wire protection should be selected. Their rated parameters and tripping conditions need to match the actual application.

In summary, it is generally not recommended to install circuit breakers or fuses on the neutral wire. They should be installed on the phase or hot wire according to standard installation methods to ensure the safety and efficient operation of the circuit. If there are specific requirements, it is advisable to consult with a professional electrical engineer to ensure compliance with electrical safety regulations.

  1. Can Motor Soft Starters Save Energy?

Motor soft starters can help reduce the current surge during motor startup and gradually accelerate the motor to its rated operating speed, thereby reducing the motor’s startup power demand, lowering grid impact, and extending equipment life. Therefore, motor soft starters can save energy to some extent. This is reflected in the following aspects:

  1. Reduced Grid Load: The current surge during motor startup can lead to a sharp increase in grid load. Using a soft starter can smooth the motor startup, reduce this surge, and lessen the burden on the grid, thus reducing grid operating costs.

  2. Reduced Equipment Wear: Traditional startup methods may cause significant impact and wear on the motor and transmission equipment. Soft starting allows for a slow and steady motor startup, reducing equipment wear, extending equipment life, and lowering maintenance costs.

  3. Reduced Energy Consumption: The high current surge during motor startup results in significant energy loss. Soft starters control the motor’s startup mode and speed, reducing energy consumption during startup moments and achieving energy savings.

In summary, motor soft starters can effectively reduce current surges and energy consumption during motor startup, decrease equipment wear, extend equipment life, and reduce grid load. Therefore, from the perspective of energy savings, reducing losses, and protecting equipment, motor soft starters are considered energy-saving devices.

  1. What are the starting current and starting torque of the motor when operated with a variable frequency drive (VFD)?

When operating a motor with a variable frequency drive (VFD), the starting current and starting torque of the motor are influenced by the VFD as follows:

  1. Starting Current: The VFD can control the motor’s smooth start by adjusting the output frequency and voltage. Compared to traditional direct starting methods, VFD starting can keep the starting current at a lower level, avoiding a sudden increase in grid load. During VFD startup, the motor’s current gradually increases, thereby avoiding high current surges during startup.

  2. Starting Torque: The VFD can achieve better control of the motor’s starting torque by controlling the output voltage and frequency. During the motor startup phase, the VFD can provide additional torque support, allowing the motor to start smoothly and gradually accelerate without stalling or experiencing abnormalities due to insufficient starting torque.

In summary, when operated with a VFD, the starting current and starting torque of the motor can be optimized and made smoother through VFD control. This not only reduces grid impact, reduces equipment wear, and extends motor life but also improves the stability and efficiency of motor startup, meeting the modern industrial requirements for energy efficiency, stability, and control performance. Using a VFD to control the motor not only optimizes the startup process but also enables functions such as constant torque output and speed control during operation, thereby improving motor efficiency and flexibility.

  1. Is there any connection between motor overload and short circuit?

Motor overload and short circuits are common motor failure phenomena. Although they are not directly related concepts, there are some connections between them in practical motor operation:

  1. Factors affecting both: Overload and short circuits can both cause abnormal operation or damage to the motor. Although the reasons are different, both can pose varying degrees of harm to the motor.

  2. Protective devices: To prevent serious damage caused by motor overload or short circuits, overload protection devices and short circuit protection devices are usually installed in the motor circuit. The overload protection device monitors the motor’s load condition and automatically cuts off the power when it exceeds the rated load to prevent damage to the motor. The short circuit protection device quickly disconnects the circuit to prevent the burning caused by excessive current.

  3. Fault analysis: When a motor experiences overload or short circuits, it usually requires fault detection and troubleshooting. In some cases, overload may lead to excessive heating of the motor, ultimately causing a short circuit. Conversely, a short circuit may also cause motor overload because a short circuit leads to an abnormal increase in motor current. Therefore, when diagnosing and troubleshooting motor faults, factors such as overload and short circuits need to be comprehensively considered.

While motor overload and short circuits are two different forms of faults, they often occur simultaneously or affect each other during actual motor operation. Hence, timely fault diagnosis and protection measures are crucial to ensure the safe operation of the motor. Regular inspection and maintenance of the motor, along with the proper setting of protective devices, can effectively reduce the damage caused by overload and short circuits, thereby improving the reliability and safety of the motor.

  1. What are the applications and benefits of variable frequency drives (VFD)?

Variable frequency drive (VFD) technology is a method of adjusting motor speed by controlling the supply frequency and voltage to the motor. It is widely used in various fields, including:

  1. Industrial Production: VFD technology is widely used in various industrial production processes, such as speed control of fans, pumps, compressors, conveyors, etc. Through VFDs, precise speed control is achieved, improving equipment efficiency and production quality.

  2. Manufacturing Industry: In manufacturing equipment such as machine tools, presses, injection molding machines, etc., VFDs can achieve precise control of equipment operating speed and machining accuracy, thereby improving production efficiency and reducing energy consumption.

  3. HVAC Systems: In HVAC systems, VFD technology can adjust the speed of air conditioning fans and compressors according to changes in indoor load, achieving energy-saving temperature control and improving comfort.

  4. Transportation: In transportation equipment such as elevators, electric vehicles, rail transportation, etc., VFDs can achieve smooth starting and precise speed control, improving transportation efficiency and safety.

The benefits of VFD technology include:

  1. Energy Saving: Using VFDs can reduce motor speed and power consumption when operating at partial loads, thereby reducing energy consumption and improving energy efficiency.

  2. Precise Control: VFDs enable precise control of motor speed, torque, and other parameters, adapting to different load requirements, improving production efficiency, and equipment performance.

  3. Reduced Mechanical Impact: VFDs allow smooth motor starting, avoiding startup shocks, extending equipment life, and reducing maintenance costs.

  4. Reduced Noise and Vibration: VFDs can reduce noise and vibration during motor operation, improving equipment operational stability and comfort.

In summary, VFD technology has wide applications in industrial production, manufacturing, HVAC systems, transportation, etc. It provides advantages such as energy saving, precise control, reduced mechanical impact, and decreased noise, contributing positively to improving production efficiency, energy conservation, emission reduction, and environmental quality.

  1. Using a 100KVA transformer to supply a total power of 300kW to electrical appliances (with a maximum of 37kW), is it sufficient?

Firstly, we need to calculate the total power demand when all these electrical appliances are running simultaneously. According to the information provided, the total power is 300kW, but the maximum power for each appliance is 37kW. Therefore, when all devices are running simultaneously, we take the total power as 300kW.

Next, for the calculation of the transformer capacity, it is necessary to ensure that the rated capacity of the transformer is greater than or equal to the total power demand to ensure the transformer can operate stably. In this case, with a total power demand of 300kW, the transformer should ideally have a capacity greater than or equal to 300kVA.

Therefore, using a 100kVA transformer to supply a total power of 300kW to electrical appliances is not sufficient. You may need a transformer with a larger capacity, preferably selecting a 300kVA or larger capacity transformer to meet the total power demand of these appliances. This ensures that the electrical appliances receive stable and reliable power supply, avoiding the risk of transformer overload.

  1. How to measure the insulation resistance of a motor?

Measuring the insulation resistance of a motor is an important diagnostic tool that can be used to assess the health of the motor’s insulation system. Below are the general steps for measuring the insulation resistance of a motor:

  1. Preparation: Before conducting insulation resistance testing, ensure that the motor is in a de-energized state and all power connections have been disconnected. Additionally, use insulation testing equipment such as a multimeter or insulation resistance tester for this test.

  2. Select the appropriate test voltage: Based on the motor’s rated voltage and the insulation system’s class, select the appropriate test voltage. Typically, insulation resistance testing uses test voltages of 500V or 1000V.

  3. Connect the testing instrument: Connect the testing instrument’s test leads to the two ends of the motor winding insulation system. Generally, connect one lead to the winding insulation system and the other lead to the motor casing or ground.

  4. Perform the test: Set the testing instrument to insulation resistance testing mode and then perform the measurement. Based on the measurement results, you can assess the condition of the motor’s insulation system. Generally, the insulation resistance should comply with the manufacturer’s specifications or standards.

  5. Interpret the results: Based on the test results, you can determine the health status of the motor’s insulation system. Typically, higher insulation resistance values indicate better insulation systems, while lower values may indicate insulation issues that require further investigation or repair.

Safety precautions:

  • Avoid conducting insulation resistance testing in damp environments to prevent affecting the test results.
  • Handle the testing process with care to ensure correct instrument connections and strictly follow safety protocols.
  • If the test results show abnormally low insulation resistance, it may indicate insulation faults in the motor, which should be promptly addressed through maintenance or replacement.
  1. What is a brushless sensorless starter?

A brushless sensorless starter refers to a starter device used in brushless motor systems, also known as a brushless starter. A brushless motor is a type of motor that does not require carbon brushes to establish electrical contact between the rotor and the stator. The brushless starter is a device used to initiate the operation of a brushless motor.

In traditional DC motors, carbon brushes are typically used to provide current to the rotor, enabling it to rotate. In contrast, brushless motors utilize electronic commutation to control the current flow, eliminating the need for carbon brushes and making them more reliable and efficient. Brushless motors are particularly suitable for applications requiring high-speed and efficient operation.

A brushless sensorless starter is primarily used to initiate the operation of a brushless motor, allowing it to operate without external carbon brushes. “Sensorless” refers to the absence of position sensors such as Hall effect sensors or encoders, which are commonly used in brushless motor systems. Instead, the motor controller utilizes sophisticated algorithms to determine the rotor position based on the back electromotive force (EMF) generated by the motor windings during operation.

The brushless sensorless starter typically includes a dedicated controller that provides appropriate current and voltage to the brushless motor, enabling precise starting and operation.

Advantages of brushless sensorless starters include:

  1. High reliability: Brushless motors eliminate the need for carbon brushes, reducing wear and improving motor reliability.
  2. High efficiency: Brushless motors operate more efficiently due to the absence of carbon brush friction, resulting in significant energy savings.
  3. Longevity: Brushless motors have longer lifespans because they do not suffer from carbon brush wear.
  4. Precise control: Brushless motors, controlled by electronic commutation, allow for precise control of parameters such as speed and torque.

In applications requiring high efficiency, precision control, and reliability, the combination of a brushless sensorless starter and brushless motor can offer superior performance.

  1. How many types of motor capacitor starting methods are there?

Capacitor starting is a common method for starting electric motors, which provides sufficient starting torque by introducing a phase difference using capacitors during startup to smoothly start the motor. The main types of capacitor starting methods include:

  1. Starting Capacitor Method: This is the most common capacitor starting method, where a starting capacitor is used to provide auxiliary phase difference to the motor during startup. After startup, the capacitor automatically disconnects or switches to a running capacitor.

  2. Split-phase Capacitor Starting Method: In this method, the starting capacitor is disconnected after the motor starts, and the motor switches to running on a running capacitor. This reduces the capacitance and improves the power factor of the motor.

  3. Dual Capacitor Starting Method: This method utilizes two capacitors, one for starting and one for running. After the motor starts, the starting capacitor automatically disconnects, and the motor continues to run on the running capacitor.

  4. Star-Delta Starting Method: Similar to star-delta starting, this method initially starts in a star connection and then switches to a delta connection for running. Capacitors generate additional starting torque during the starting phase.

  5. Light Load High-capacity Method: In this method, high-capacity capacitors are used to provide additional starting torque during light-load startup, assisting the motor in smooth starting.

These are common capacitor starting methods, and the choice of starting method depends on the type of motor, its power rating, and the operating conditions. Selecting the appropriate capacitor starting method can effectively improve the motor’s starting performance and reduce its impact on the motor itself and the power grid during startup. When choosing a motor capacitor starting method, it is essential to consider specific application requirements and motor characteristics.

  1. A plastic extrusion equipment controlled by a variable frequency drive (VFD) has been running for over a year. Currently, the VFD displays motor overload after running for one hour. Is this a motor problem or a VFD problem?

Based on your description, when the plastic extrusion equipment runs for one hour, the VFD displays a motor overload fault. This could be caused by either a problem with the motor itself or a problem with the VFD. To accurately diagnose the fault, consider the following points:

  1. Motor Issue: The motor overload may be caused by problems with the motor itself. If the motor experiences an overload during operation, it may trigger the corresponding fault indication on the VFD. Check if the motor is subjected to overload conditions or if there are issues such as increased rotor resistance.

  2. VFD Issue: The VFD could also be a potential cause of the fault. The VFD controls the motor’s speed and current, and it displays fault indications when the motor encounters issues. Possible causes include incorrect VFD settings, parameter misconfigurations, or VFD malfunctions.

To accurately determine whether the issue lies with the motor or the VFD, consider the following steps:

  • Check the motor and drive system: Look for any abnormal sounds, heating, bearing sliding, or fan malfunctions in the motor. Check if the motor is obstructed or if there are any faults present.

  • Verify VFD parameters: Ensure that the VFD parameters are correctly set, including rated current, overload capacity, overload time, etc., to ensure compatibility with the motor.

  • Conduct testing: Perform short-duration tests under non-overload conditions to observe the motor’s operation and determine if overload conditions persist.

If after these checks you are still unable to determine the cause of the fault, it is recommended to seek assistance from professional technicians or engineers for further diagnosis and repair to accurately identify whether the issue lies with the motor or the VFD and to perform the necessary maintenance or adjustments.

  1. Can a transformer be used as a load for a variable frequency drive (VFD)?
Typically, a transformer cannot be used as a load for a variable frequency drive (VFD) because a transformer is designed to change voltage, not frequency. A VFD, on the other hand, is used to alter the frequency of the power supply to control the speed and operation of motors. Attempting to use a transformer as a load for a VFD may lead to circuit faults, equipment damage, or hazardous conditions. Therefore, it is generally not recommended to use a transformer as a load for a VFD.
  1. Can a variable frequency drive (VFD) be adjusted to 1Hz, and what is the maximum frequency it can be adjusted to?
Most modern variable frequency drives (VFDs) can adjust the frequency to as low as 1Hz. Typically, the frequency range of a VFD is between 0 and several hundred Hertz, depending on the brand and model of the VFD. In general, common VFDs can reach a maximum frequency of several hundred Hertz, with three-phase VFDs commonly reaching up to 400 Hertz. When selecting a VFD for practical use, it is essential to choose one that meets the specific application requirements and equipment specifications to ensure that its frequency range meets the needs.
  1. How does the frequency adjustment resistor in a variable frequency drive (VFD) work? Why can adjusting the resistor change the frequency?

The working principle of the frequency adjustment resistor in a variable frequency drive (VFD) is based on the internal control circuit and electronic components of the VFD. Inside the VFD, there is typically a control circuit for adjusting the output frequency, and this circuit uses a resistor to achieve frequency adjustment.

Specifically, within the VFD, the frequency control circuit controls the oscillation frequency of the circuit through the resistor. When the resistance value of the adjustment resistor changes, the operating frequency of the frequency control circuit also changes, thereby causing the output frequency of the VFD to change accordingly. This principle relies on adjusting the influence of electronic components (such as capacitors, inductors, etc.) in the control circuit on the frequency.

The reason why adjusting the resistor can change the frequency is that by changing the resistor in the circuit, the circuit’s parameters can be altered, thereby affecting the circuit’s oscillation frequency. The frequency control circuit inside the VFD utilizes this principle to adjust the oscillation frequency of the circuit by adjusting the resistor, thereby controlling the output frequency of the VFD. This allows for the control of the VFD output frequency by adjusting the resistor.

  1. How to calculate generator power?

Generator power can be calculated using the following formula:

Power (P) = Voltage (V) × Current (I) × Power Factor (PF) × Time (t)

Where:

  • Voltage (V) is the output voltage of the generator (unit: volts, V).
  • Current (I) is the output current of the generator (unit: amperes, A).
  • Power Factor (PF) is the phase relationship between current and voltage, typically assumed to be 1 for calculation purposes.
  • Time (t) is the measurement period for power (unit: seconds, s).

In practical calculations, the output voltage and current of the generator are usually measured first, and then the power of the generator is calculated using the formula. It’s important to note that the power factor is a critical parameter. It’s often assumed to be 1 to simplify calculations, but in reality, the power factor of the equipment will affect the calculation results.

  1. Can a variable frequency drive decouple motor current?

Yes, a variable frequency drive (VFD) can decouple the current of a motor. The motor current typically consists of two components: active current and reactive current. The active current is used to generate mechanical power, while the reactive current is used to create the magnetic field. By controlling the output voltage and frequency, a VFD can decouple the current of the motor, meaning it can control the direction and magnitude of both active and reactive currents separately.

By adjusting the output voltage and frequency of the VFD, various operating characteristics of the motor can be controlled, including torque, speed, power, and efficiency. During the control process, the proportion of active and reactive currents can be adjusted according to the requirements, allowing the motor to achieve optimal performance under different conditions. This decoupling control method can improve the efficiency of motor operation, reduce energy consumption, and achieve more precise control.

  1. Why does the current of an induction motor increase during startup and decrease after startup?

There are two main reasons why the current of an induction motor is higher during startup and decreases after startup:

  1. Starting torque requirements: When an induction motor starts, it needs to overcome factors such as static friction and inertia to generate sufficient starting torque. During startup, the motor’s rotor is at rest, requiring a higher current to produce enough rotational torque to initiate motor rotation. Therefore, a higher current is needed during startup to provide the necessary torque.

  2. Reduction of starting current: The starting current of an induction motor gradually decreases as the rotor transitions from a stationary state to a running state. This is because the rotor current in an induction motor is induced by the induction effect. As the rotor begins to rotate, the induced current gradually decreases. Additionally, the motor’s self-induced electromotive force (back EMF) contributes to reducing the current. As a result, the high current level required during startup is no longer necessary after the motor has started. The high starting current during startup allows the motor to quickly reach its rated operating state within a short period. Subsequently, the current gradually decreases to the rated operating state, saving energy and extending the equipment’s lifespan.

  1. How does carrier frequency affect the variable frequency drive (VFD) and motor?

Carrier frequency refers to the high-frequency signal used to modulate the direct current voltage in pulse-width modulation (PWM) technology. This pulse signal effectively converts the direct current voltage into alternating current voltage, thereby driving the AC motor and achieving speed control by the VFD. Carrier frequency can affect the VFD and motor in the following ways:

  1. Electromagnetic interference: Carrier frequency affects electromagnetic interference in the VFD circuitry. Higher carrier frequencies increase the high-frequency components of the PWM waveform, which may cause electromagnetic interference, affecting circuit stability and electromagnetic compatibility.

  2. Efficiency: Proper selection of carrier frequency can improve the efficiency of the VFD system. Too low carrier frequency may cause motor noise and affect motor energy efficiency, while too high carrier frequency increases switching losses in the VFD, reducing system efficiency.

  3. Electromagnetic noise: Carrier frequency affects electromagnetic interference and noise in the system. Higher frequencies may interfere with nearby communication and electronic devices. Therefore, an appropriate carrier frequency should be selected to balance system efficiency and electromagnetic compatibility.

  4. Torque smoothness: Proper selection of carrier frequency can achieve smooth torque control of the motor by the VFD. Reasonable carrier frequency settings can make the motor speed adjustment process smoother, reducing vibration and noise.

In summary, carrier frequency has a significant impact on both the VFD and motor. It is essential to choose the appropriate carrier frequency based on actual application requirements to balance factors such as electromagnetic compatibility, efficiency, and torque smoothness.

  1. Why can’t a variable frequency drive (VFD) be used as a power source for frequency conversion?

A variable frequency drive (VFD) is a device used to control the speed of an AC motor by adjusting the output voltage and frequency. Although a VFD can provide AC power with different frequencies, it is not suitable for direct use as a power source for frequency conversion due to the following reasons:

  1. Output Voltage Waveform: The output of a VFD is generally a pulse-width modulation (PWM) controlled square wave signal, rather than a traditional sinusoidal AC power supply. This square wave signal waveform can cause harmonic pollution and high-frequency noise, potentially damaging or interfering with nonlinear loads and lighting fixtures.

  2. Power Supply Stability: VFDs typically require single-phase or three-phase AC inputs, and their input power must meet certain voltage and frequency requirements. Using a VFD directly as a power source for frequency conversion may result in mismatched input parameters, affecting the stability of equipment operation.

  3. Insufficient Power Capacity: As a device for controlling motor speed, VFDs typically have relatively small power capacities and cannot meet the power supply requirements of high-power electrical equipment such as household appliances and industrial machinery.

  4. Circuit Protection: VFDs usually have protection functions such as overload, short circuit, overvoltage, and undervoltage protection. However, these protection functions may not be effective when supplying power to external devices as a frequency conversion power source, leading to inadequate protection for the connected equipment.

Therefore, while VFDs offer excellent performance and precision in controlling motor speed, limitations in output waveform, power supply stability, power capacity, and protection functions prevent their direct use as power sources for frequency conversion. In practical applications, it is necessary to choose appropriate power supply equipment based on the power supply requirements of the equipment to ensure stable operation and safety.

  1. Why does the motor temperature rise higher when using a variable frequency drive (VFD) compared to line frequency operation?

When using a variable frequency drive (VFD) to drive a motor, several factors contribute to the higher temperature rise compared to line frequency operation:

  1. High Frequency Operation: With a VFD, the motor’s operating frequency can be adjusted, often leading to operation at higher frequencies. Higher frequencies result in increased eddy current losses in the motor’s iron core and windings, leading to higher heat generation at rated power.

  2. PWM Controlled Pulse Signals: VFDs use pulse-width modulation (PWM) to convert DC power to AC power, creating high-frequency pulse signals to control the motor. Unlike traditional sinusoidal AC power sources, these pulse signals cause additional high-frequency losses in the motor during operation, contributing to higher temperature rise.

  3. Current Harmonics: The pulse signals generated by the VFD may introduce current harmonics, causing the motor’s current waveform to deviate from a sinusoidal shape and increasing harmonic losses, thereby raising the motor’s temperature.

  4. Torque Control: During low-speed and high-torque startup conditions, the VFD may need to supply higher currents to meet the motor’s requirements, resulting in additional losses in these operating conditions and contributing to higher temperature rise.

Therefore, when using a VFD to drive a motor, factors such as high frequency operation, PWM controlled pulse signals, current harmonics, and torque control contribute to increased losses and higher temperature rise compared to traditional line frequency operation. In practical applications, it is important to consider the VFD’s frequency and control parameters, and choose appropriate settings to ensure safe motor operation and effectively reduce temperature rise.

  1. What does the protection level of a motor mean?

The protection level of a motor refers to the degree of protection provided by the motor’s enclosure against external objects, water, and other substances. It is typically expressed using the IP (Ingress Protection) rating system. The IP rating consists of two digits, where the first digit indicates the level of protection against solid objects and the second digit indicates the level of protection against liquids. The IP rating represents the sealing level of the equipment, indicating its resistance to dust, water, particles, and other external substances to ensure stable and safe operation.

Here are common representations of IP ratings:

  1. Protection Against Solids: The first digit represents the protection against solid objects, ranging from 0 to 6. A higher number indicates a stronger protection level against solid objects. For example, 0 means no special protection, and 6 means complete protection against dust.

  2. Protection Against Liquids: The second digit represents the protection against liquids, ranging from 0 to 9. A higher number indicates a stronger protection level against liquids. For example, 0 means no protection, and 9 means protection against high-pressure jets.

For example, if a motor has an IP66 protection rating, it means that it has a high level of protection against both solid objects and liquids. IP6 indicates complete protection against dust, and IP6 indicates protection against water jets. Therefore, this motor can operate in harsh environments without being affected by dust and water.

By understanding the protection level of a motor, users can choose a motor with the appropriate protection level based on the requirements of the operating environment, ensuring stable operation and extending the motor’s lifespan.

NEXT

Purchase high-performance vector frequency inverter directly by clicking the link below.

Last updated on